Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
REGULATOR , ENGINE GENERATOR

Definition:

A REGULATOR DESIGNED TO AUTOMATICALLY MAINTAIN THE CURRENT AND/OR VOLTAGE OUTPUT OF AN ENGINE GENERATOR WITHIN SPECIFIED LIMITS, REGARDLESS OF VARIATION OF LOAD OR INPUT VOLTAGES. MAY INCLUDE CUTOUT RELAY. DOES NOT INCLUDE ITEMS IN WHICH REGULATION IS ACCOMPLISHED BY TRANSFORMER ACTION. SEE ALSO REGULATOR, CURRENT AND REGULATOR, VOLTAGE.

CAGE Information

Code Company
1LW55 REMY INC.

Federal Supply Class

Title

ENGINE ELECTRICAL SYSTEM COMPONE

Inclusions:

INCLUDES GENERATORS; MAGNETOS; SPARK PLUGS; IGNITION COILS; IGNITION DISTRIBUTORS; ENGINE VOLTAGE REGULATORS; IGNITION HARNESS ASSEMBLIES; STARTING MOTORS FOR ENGINES.

Exclusions:

EXCLUDES VEHICULAR LIGHTING FIXTURES (FSC 6220) AND AIRCRAFT GENERATORS (FSC 2925).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ANYX CUTOUT VOLTAGE RATING NOT RATED
ANYD SYSTEM GROUND POLARITY NEGATIVE
APAK CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH AND HOLE ALONG LENGTH 5.075 NOMINAL CENTIMETERS
ADNZ DISTANCE BETWEEN HOLES ALONG WIDTH 1.485 INCHES MINIMUM
ANYC SYSTEM VOLTAGE RATING 12.0
AARB TERMINAL TYPE CONNECTOR, RECEPTACLE W/INTERNAL CONTACTS
ANYD SYSTEM GROUND POLARITY POSITIVE
ANYH VOLTAGE REGULATOR UNIT QUANTITY 1
ADNZ DISTANCE BETWEEN HOLES ALONG WIDTH 1.515 INCHES MAXIMUM
ABTB MOUNTING HOLE DIAMETER 0.282 NOMINAL CENTIMETERS
ABTB MOUNTING HOLE DIAMETER 0.272 NOMINAL MILS
ANPP OUTPUT VOLTAGE RATING IN VOLTS 14.3 MAXIMUM
ANZB REVERSE CURRENT OVERLOAD CIRCUIT BREAKER NOT INCLUDED
ANYR CIRCUIT CONTROL DEVICE TYPE SOLID STATE CIRCUIT BOARD
ANYE VOLTAGE REGULATOR UNIT TYPE TRANSISTOR
ADER MOUNTING STYLE THREE HOLE TRIANGULAR
ADZC ENVIRONMENTAL PROTECTION CORROSION RESISTANT
AGBC SHOCK MOUNT NOT PROVIDED
ANYZ CUTOUT CURRENT RATING IN AMPS NOT RATED
ANZF CONDUIT CONNECTION QUANTITY 1
ALBH RADIO INTERFERENCE SHIELDING NOT PROVIDED
ANZC FIELD RELAY UNIT NOT INCLUDED
ANPP OUTPUT VOLTAGE RATING IN VOLTS 13.7 MINIMUM
ANYS CUT-IN VOLTAGE RATING NOT RATED
AARA TERMINAL QUANTITY 3
ADZC ENVIRONMENTAL PROTECTION WATERTIGHT
APAK CENTER TO CENTER DISTANCE BETWEEN HOLES ALONG WIDTH AND HOLE ALONG LENGTH 5.045 NOMINAL MILS
ANZE TERMINAL ENCASEMENT ENCASED

Similar Parts

9 000 590 , 9000590 , 2920-00-961-8262 , 2920009618262 , 009618262